48V Lithium ion Battery

48V Lithium ion battery

Delta Telecom Battery · Available through Mpower India

Delta 48V 57Ah Lithium-Ion Battery for Telecom & Data Center DC Backup

Looking for a compact 48V lithium-ion battery for telecom DC plants, network cabinets or datacom infrastructure? Compare the published Delta 57Ah NMC battery specifications, plan a safe lead-acid retrofit and request a configuration-specific quote from Mpower.

Designed for 48V-class DC backup installations, this 19-inch rack-mounted battery integrates a Battery Management System (BMS), remote-monitoring interfaces and cell-level protection features. Charger compatibility, available backup duration and installation design must be confirmed for your site.

48.1V nominal57Ah nominal19-inch rackCAN · RS485≥4,000 cycles @ 25°C
Enquire on WhatsApp
At a glance

Know the Battery Before You Specify It

2.74 kWh

Nominal theoretical stored energy (48.1V × 57Ah); usable energy is lower and varies by operating conditions.
100A

Manufacturer’s published maximum discharge current—not a continuous site-power guarantee.
≈27 kg

Approximate module weight; check rack load, handling clearances and enclosure layout.
Delta rack-mounted 48V lithium-ion battery module pictured on Mpower India's website
Real product image from Mpower

Compact rack-mount format

The published module dimensions are 429 × 430 × 118 mm (L × W × H), with 19-inch rack mounting and IP20 protection.

  • NMC lithium-ion chemistry
  • Front access and status indication
  • CAN 2.0B, RS485 and dry-contact interfaces
  • Rated charge voltage of 53.3V

Photograph is illustrative of the listed Delta battery product. Confirm the current supplied revision and its exact appearance.

OEM reference data

Delta 48V Lithium-Ion Battery Technical Specifications

Unlike a generic “48V lithium battery” listing, this product has specific electrical, mechanical and communication ratings. The values below come from Delta Electronics India’s published specification. Confirm current revision and model code before ordering.



Electrical parameter Published rating
Cell chemistry Lithium-ion NMC system
Nominal voltage 48.1 V
Nominal capacity 57 Ah
Nominal energy (calculated) Approximately 2.74 kWh (48.1V × 57Ah)
Charging voltage 53.3 V
Operating voltage range 42.0–53.6 V
Discharge cut-off voltage 42.0 V
Maximum charging current 50 A
Maximum discharge current 100 A

Figures are reference specifications for the Delta 48.1V / 57Ah NMC product and are not transferable to every 48V lithium-ion or LiFePO₄ (LFP) battery. Ratings may vary by exact model and operating conditions.

Official Delta Data ↗
Interactive planning tool

Preliminary Backup Battery Energy Estimator

Enter the steady DC equipment load and desired backup time to understand the approximate battery energy required. This simplified tool is for early-stage enquiries—not engineering approval or a guaranteed runtime estimate.

Example: telecom DC equipment draws 500W.
Choose target runtime, not battery warranty duration.
Planning assumption only, not a Delta-prescribed depth of discharge.
Use your rectifier/distribution design for real system losses.

Indicative nominal battery energy needed1.39 kWh

Energy-only equivalent: 1 × 2.74kWh nominal module.

Computed using 80% usable allowance and 90% system efficiency. Battery count is NOT an approved electrical configuration.

Send Calculated Requirement ↗

Engineering note: The module has a published 100A maximum discharge limit. Final bank sizing must separately account for per-module current, battery discharge curves, temperature, aging, BMS limits, charger compatibility, allowable parallel units, protective devices, cabling and your actual load profile. Never assume modules can be added in parallel without approval.
Lead-acid to lithium upgrade

Is This 48V Battery Compatible With Your Telecom DC System?

Delta describes the module as a retrofit option for lead-acid battery packs. That does not mean every VRLA installation can be replaced without modifications. Verify the full DC plant before installation.

AC Supply +
Rectifier / Charger
↔48V DC Bus
& Distribution
↔Delta Battery
& BMS
→Telecom /
Network DC Loads

Conceptual system overview only, not a wiring diagram. DC polarity, isolation and switching must follow the OEM-approved installation design.

Pre-Retrofit Compatibility Checklist

Tick the items you can already document. Anything unverified should be assessed by the installation engineer before quotation approval.






0 of 6 checks documented — engineering validation required in every case.

Where this system belongs

Applications for Delta 48V DC Backup Batteries

Telecom Towers & 4G/5G Sites

Battery backup for compatible 48V telecom DC rectifier plants, mobile base stations and distributed network locations.

Fiber & Fixed-Line Networks

Supports power continuity planning for compatible exchange, broadband and access-network DC infrastructure.

Edge & Datacom Systems

For critical datacom equipment designed around compatible 48V DC supply; not a direct substitute for AC UPS batteries.

Remote Network Cabinets

Rack-friendly energy storage for distributed sites where reliable DC backup and supported remote status monitoring matter.

Battery safety & integration

BMS, Monitoring & Lifecycle Considerations

Safety Monitoring

  • Temperature and abnormal operating-condition protection
  • Overcharge and overdischarge safeguards
  • On-module status indication and front access
  • System alarms subject to actual interface integration

Battery Lifecycle & Ownership

  • Manufacturer-referenced cycle life ≥4,000 at 25°C
  • Lower routine battery maintenance than many lead-acid installations
  • Space and mass savings in compatible racks
  • TCO depends on purchase cost, temperatures, battery use and project design

Remote monitoring through CAN 2.0B, RS485 or dry-contact signals depends on the monitoring gateway, controller, protocol support and integration scope. Confirm which signals will actually be visible before promising multi-site dashboards or predictive analytics.

Buying from Mpower

What to Share for an Accurate 48V Lithium Battery Quote

1

Application and site

Telecom tower, fiber node, edge rack or other compatible 48V DC installation; specify city and installation conditions.

2

Current system details

Rectifier make/model, existing battery chemistry/capacity, nominal DC bus voltage and controller/BMS interface expectations.

3

Load and target backup duration

Provide DC load in watts or amps, inrush peaks, desired autonomy and any rack, temperature or outage constraints.

4

Commercial and commissioning scope

Required quantity, delivery city, installation/commissioning assistance and requested documentation. Availability and warranty are quotation-specific.

Explore Mpower Lithium-Ion Solutions →
Frequently asked questions

48V Lithium-Ion Battery FAQs

Is this Delta lithium-ion battery 48V or 48.1V?

It is designed for 48V-class DC applications. Delta lists a nominal voltage of 48.1V for the specified NMC battery system and a published 42.0–53.6V working range.

What is the nominal energy of a Delta 48.1V 57Ah battery?

Multiplying the published nominal voltage and nominal capacity gives approximately 2.74kWh of theoretical nominal stored energy. Usable energy and runtime are lower or variable because of operating limits, temperature, battery aging and system losses.

Can I directly replace a 48V VRLA or lead-acid battery bank?

Delta lists lead-acid retrofit as an application, but it is not universally plug-and-play. The charger profile, rectifier/controller, BMS interfaces, cabling, current limits and rack layout must be checked for compatibility before replacing an existing bank.

Can this battery be used with a normal 230V AC online UPS?

Not without specific OEM and engineering approval. This product is intended for compatible 48V DC backup plants; many AC UPS systems use different battery voltages, battery strings, chargers and communication methods.

What is the maximum charging or discharge current?

Delta’s reference specification states a maximum charging current of 50A and maximum discharge current of 100A. Actual allowable operation depends on the specific unit, configuration, temperature and BMS behavior.

How long does a 48V 57Ah lithium-ion battery last?

Delta publishes a cycle life of at least 4,000 cycles at 25°C under its defined conditions. Actual service life varies by operating temperature, charge/discharge depth and daily usage. It is not equivalent to a guaranteed number of years.

Does this battery support RS485 and CAN monitoring?

Yes. The published interfaces include RS485, CAN 2.0B (500kHz) and dry contacts. The actual monitoring information accessible to your site depends on integration compatibility and the specific controller or gateway.

Is the battery LFP (LiFePO4) or NMC?

This particular Delta 48.1V, 57Ah product is described by the manufacturer as an NMC lithium-ion system. Do not substitute specifications from another Delta LFP model.

Can I combine multiple 48V modules for longer backup?

Additional modules may be part of an engineered solution, but the allowable topology and unit count must be validated against the exact battery model, BMS and rectifier/controller. Do not parallel modules based on voltage rating alone.

How can I get the Delta 48V lithium-ion battery price in India?

Request a quotation from Mpower India with your required quantity, installation location, DC system details and backup target. Final pricing depends on the approved product model, availability, site requirements and commissioning scope.

Related Mpower solutions

Choose the battery technology and power architecture that actually fit the application. The products below are separate categories and are not automatically interchangeable.

Mpower India · Navi Mumbai

Request the Right 48V Battery Configuration

Tell us your 48V DC plant model, load, required backup duration and site location. We can review the requirement and help prepare a quotation for a technically appropriate Delta battery solution.

WhatsApp Requirement ↗

MPower India Private Limited · Akshar Business Park, Sector 25, Vashi, Navi Mumbai · +91 7977741332

Get Quote

Download Brochure

    Download Brochure

      Download Brochure

        Download Brochure

          Download Brochure

            Download Brochure

              Download Brochure

                Download Brochure

                  Download Brochure

                    Download Brochure

                      Download Brochure

                        Download Brochure

                          Download Brochure

                            Download Brochure

                              Download Brochure

                                Download Brochure

                                  Download Brochure

                                    Download Brochure

                                      Download Brochure

                                        Download Brochure

                                          Download Brochure

                                            Download Brochure