Delta 48V 57Ah Lithium-Ion Battery for Telecom & Data Center DC Backup
Looking for a compact 48V lithium-ion battery for telecom DC plants, network cabinets or datacom infrastructure? Compare the published Delta 57Ah NMC battery specifications, plan a safe lead-acid retrofit and request a configuration-specific quote from Mpower.
Designed for 48V-class DC backup installations, this 19-inch rack-mounted battery integrates a Battery Management System (BMS), remote-monitoring interfaces and cell-level protection features. Charger compatibility, available backup duration and installation design must be confirmed for your site.
Know the Battery Before You Specify It
Compact rack-mount format
The published module dimensions are 429 × 430 × 118 mm (L × W × H), with 19-inch rack mounting and IP20 protection.
- NMC lithium-ion chemistry
- Front access and status indication
- CAN 2.0B, RS485 and dry-contact interfaces
- Rated charge voltage of 53.3V
Photograph is illustrative of the listed Delta battery product. Confirm the current supplied revision and its exact appearance.
Delta 48V Lithium-Ion Battery Technical Specifications
Unlike a generic “48V lithium battery” listing, this product has specific electrical, mechanical and communication ratings. The values below come from Delta Electronics India’s published specification. Confirm current revision and model code before ordering.
| Electrical parameter | Published rating |
|---|---|
| Cell chemistry | Lithium-ion NMC system |
| Nominal voltage | 48.1 V |
| Nominal capacity | 57 Ah |
| Nominal energy (calculated) | Approximately 2.74 kWh (48.1V × 57Ah) |
| Charging voltage | 53.3 V |
| Operating voltage range | 42.0–53.6 V |
| Discharge cut-off voltage | 42.0 V |
| Maximum charging current | 50 A |
| Maximum discharge current | 100 A |
| Mechanical / environment | Published rating |
|---|---|
| Dimensions (L × W × H) | 429 × 430 × 118 mm |
| Weight | Approximately 27 kg |
| Rack installation | 19-inch rack mounting |
| Ingress protection | IP20 |
| Charging temperature | 0°C to +50°C |
| Discharging temperature | −20°C to +50°C |
| BMS / compliance | Published information |
|---|---|
| Cycle life at 25°C | ≥4,000 cycles under OEM test conditions |
| Interfaces | CAN 2.0B (500 kHz), RS485, dry contact |
| BMS safeguards | Abnormal temperature, overcharge and overdischarge protection; OEM-listed monitoring |
| Cell certification | UN38.3, IEC62619 |
| Pack certification | UN38.3, IEC62619, EN61000-6-1, EN61000-6-3, CNS15387:5.2.4 and 5.3.1 |
Figures are reference specifications for the Delta 48.1V / 57Ah NMC product and are not transferable to every 48V lithium-ion or LiFePO₄ (LFP) battery. Ratings may vary by exact model and operating conditions.
Preliminary Backup Battery Energy Estimator
Enter the steady DC equipment load and desired backup time to understand the approximate battery energy required. This simplified tool is for early-stage enquiries—not engineering approval or a guaranteed runtime estimate.
Energy-only equivalent: 1 × 2.74kWh nominal module.
Computed using 80% usable allowance and 90% system efficiency. Battery count is NOT an approved electrical configuration.
Is This 48V Battery Compatible With Your Telecom DC System?
Delta describes the module as a retrofit option for lead-acid battery packs. That does not mean every VRLA installation can be replaced without modifications. Verify the full DC plant before installation.
Rectifier / Charger↔48V DC Bus
& Distribution↔Delta Battery
& BMS→Telecom /
Network DC Loads
Conceptual system overview only, not a wiring diagram. DC polarity, isolation and switching must follow the OEM-approved installation design.
Pre-Retrofit Compatibility Checklist
Tick the items you can already document. Anything unverified should be assessed by the installation engineer before quotation approval.
0 of 6 checks documented — engineering validation required in every case.
Applications for Delta 48V DC Backup Batteries
Telecom Towers & 4G/5G Sites
Battery backup for compatible 48V telecom DC rectifier plants, mobile base stations and distributed network locations.
Fiber & Fixed-Line Networks
Supports power continuity planning for compatible exchange, broadband and access-network DC infrastructure.
Edge & Datacom Systems
For critical datacom equipment designed around compatible 48V DC supply; not a direct substitute for AC UPS batteries.
Remote Network Cabinets
Rack-friendly energy storage for distributed sites where reliable DC backup and supported remote status monitoring matter.
BMS, Monitoring & Lifecycle Considerations
Safety Monitoring
- Temperature and abnormal operating-condition protection
- Overcharge and overdischarge safeguards
- On-module status indication and front access
- System alarms subject to actual interface integration
Battery Lifecycle & Ownership
- Manufacturer-referenced cycle life ≥4,000 at 25°C
- Lower routine battery maintenance than many lead-acid installations
- Space and mass savings in compatible racks
- TCO depends on purchase cost, temperatures, battery use and project design
Remote monitoring through CAN 2.0B, RS485 or dry-contact signals depends on the monitoring gateway, controller, protocol support and integration scope. Confirm which signals will actually be visible before promising multi-site dashboards or predictive analytics.
What to Share for an Accurate 48V Lithium Battery Quote
Telecom tower, fiber node, edge rack or other compatible 48V DC installation; specify city and installation conditions.
Rectifier make/model, existing battery chemistry/capacity, nominal DC bus voltage and controller/BMS interface expectations.
Provide DC load in watts or amps, inrush peaks, desired autonomy and any rack, temperature or outage constraints.
Required quantity, delivery city, installation/commissioning assistance and requested documentation. Availability and warranty are quotation-specific.
48V Lithium-Ion Battery FAQs
Is this Delta lithium-ion battery 48V or 48.1V?
It is designed for 48V-class DC applications. Delta lists a nominal voltage of 48.1V for the specified NMC battery system and a published 42.0–53.6V working range.
What is the nominal energy of a Delta 48.1V 57Ah battery?
Multiplying the published nominal voltage and nominal capacity gives approximately 2.74kWh of theoretical nominal stored energy. Usable energy and runtime are lower or variable because of operating limits, temperature, battery aging and system losses.
Can I directly replace a 48V VRLA or lead-acid battery bank?
Delta lists lead-acid retrofit as an application, but it is not universally plug-and-play. The charger profile, rectifier/controller, BMS interfaces, cabling, current limits and rack layout must be checked for compatibility before replacing an existing bank.
Can this battery be used with a normal 230V AC online UPS?
Not without specific OEM and engineering approval. This product is intended for compatible 48V DC backup plants; many AC UPS systems use different battery voltages, battery strings, chargers and communication methods.
What is the maximum charging or discharge current?
Delta’s reference specification states a maximum charging current of 50A and maximum discharge current of 100A. Actual allowable operation depends on the specific unit, configuration, temperature and BMS behavior.
How long does a 48V 57Ah lithium-ion battery last?
Delta publishes a cycle life of at least 4,000 cycles at 25°C under its defined conditions. Actual service life varies by operating temperature, charge/discharge depth and daily usage. It is not equivalent to a guaranteed number of years.
Does this battery support RS485 and CAN monitoring?
Yes. The published interfaces include RS485, CAN 2.0B (500kHz) and dry contacts. The actual monitoring information accessible to your site depends on integration compatibility and the specific controller or gateway.
Is the battery LFP (LiFePO4) or NMC?
This particular Delta 48.1V, 57Ah product is described by the manufacturer as an NMC lithium-ion system. Do not substitute specifications from another Delta LFP model.
Can I combine multiple 48V modules for longer backup?
Additional modules may be part of an engineered solution, but the allowable topology and unit count must be validated against the exact battery model, BMS and rectifier/controller. Do not parallel modules based on voltage rating alone.
How can I get the Delta 48V lithium-ion battery price in India?
Request a quotation from Mpower India with your required quantity, installation location, DC system details and backup target. Final pricing depends on the approved product model, availability, site requirements and commissioning scope.
Explore Compatible Backup Power Categories
Choose the battery technology and power architecture that actually fit the application. The products below are separate categories and are not automatically interchangeable.
Request the Right 48V Battery Configuration
Tell us your 48V DC plant model, load, required backup duration and site location. We can review the requirement and help prepare a quotation for a technically appropriate Delta battery solution.