Two Phase Immersion Cooling

Delta Two Phase Immersion Cooling – Two Phase Immersion Cooling

As data centers continue to support increasingly demanding workloads such as artificial intelligence (AI), machine learning, cloud computing, big data analytics, and high-performance computing (HPC), traditional air-cooling systems are reaching their operational limits. Modern processors and high thermal design power (TDP) chips generate significant amounts of heat, requiring more advanced and efficient cooling technologies.

Delta Two Phase Immersion Cooling is an innovative thermal management solution specifically designed to address the cooling challenges of next-generation data centers. By utilizing advanced liquid immersion cooling technology, Delta delivers exceptional cooling performance, significantly lower energy consumption, and improved operational efficiency compared to traditional air-cooling systems.

The solution directly immerses servers, electronic components, and IT equipment into a specially engineered non-conductive coolant. Heat generated by the equipment causes the coolant to change phase from liquid to vapor, efficiently removing thermal energy through the natural phase-change process. This innovative mechanism eliminates multiple heat exchange stages commonly found in conventional cooling systems, resulting in superior heat transfer efficiency and substantial energy savings.

How Two Phase Immersion Cooling Works

Unlike conventional air-cooling methods that rely on fans, air circulation, and multiple cooling stages, Delta’s Two Phase Immersion Cooling technology directly cools the heat source.

The cooling process includes:

  • Electronic components are fully immersed in a non-conductive dielectric coolant.
  • Heat generated by processors and IT equipment causes the coolant to boil.
  • The coolant absorbs heat and changes from liquid to vapor.
  • Vapor rises and condenses on a cooling surface.
  • The condensed coolant returns to the tank for continuous cooling.

This highly efficient cycle continuously removes heat while maintaining optimal operating temperatures for critical IT equipment.

Key Features

Ultra-Low Power Usage Effectiveness (PUE)

Delta’s Two Phase Immersion Cooling system is engineered to achieve an exceptionally low Power Usage Effectiveness (PUE) of less than 1.08.

Benefits include:

  • Improved data center energy efficiency.
  • Reduced operational costs.
  • Lower environmental impact.
  • Enhanced sustainability performance.
  • Better utilization of electrical infrastructure.

A lower PUE means more power is used for computing rather than cooling, maximizing overall data center efficiency.

High Cooling Capacity

The system delivers a cooling capacity of up to 100kW per tank, making it ideal for high-density computing environments.

Advantages include:

  • Support for high-performance computing applications.
  • Efficient cooling for AI and GPU-intensive workloads.
  • Reduced infrastructure footprint.
  • Greater computing density per rack.
  • Improved scalability for future expansion.

This high cooling capacity allows organizations to deploy powerful computing resources without concerns about thermal limitations.

Significant Energy Savings

Compared to traditional air-cooling systems, Delta’s immersion cooling technology can reduce cooling power consumption by up to 84%.

Benefits include:

  • Lower electricity costs.
  • Reduced cooling infrastructure requirements.
  • Improved return on investment.
  • Enhanced energy efficiency.
  • Reduced carbon footprint.

These savings help organizations meet sustainability goals while lowering long-term operational expenses.

Superior Thermal Performance

The direct-contact cooling approach removes heat more efficiently than air cooling by minimizing thermal resistance and eliminating unnecessary heat transfer stages.

Performance benefits include:

  • Faster heat dissipation.
  • Stable operating temperatures.
  • Reduced thermal hotspots.
  • Improved hardware reliability.
  • Enhanced equipment lifespan.

Seismic Protection and Reliability

Delta’s Two Phase Immersion Cooling system is designed to operate reliably even in challenging environments.

Key reliability features include:

  • GR-63 Zone 4 seismic certification.
  • Protection against Richter Magnitude 8 seismic events.
  • Robust mechanical design.
  • Enhanced equipment safety.
  • Reliable performance for mission-critical applications.

These capabilities make the solution suitable for deployment in regions with strict seismic safety requirements.

Benefits of Two Phase Immersion Cooling

Organizations adopting Delta Two Phase Immersion Cooling can experience numerous operational and financial advantages.

Increased Data Center Efficiency

The highly efficient cooling process reduces overall facility power consumption while supporting greater computing performance.

Higher Rack Density

Immersion cooling enables deployment of high-density servers and advanced processors without the thermal limitations associated with traditional cooling systems.

Reduced Infrastructure Requirements

The elimination of extensive air-cooling infrastructure reduces space requirements and simplifies facility design.

Sustainability and Environmental Benefits

By significantly reducing cooling energy consumption, organizations can lower greenhouse gas emissions and support green data center initiatives.

Improved Equipment Reliability

Stable temperatures and efficient heat removal help extend hardware lifespan and reduce equipment failure risks.

Applications

Delta Two Phase Immersion Cooling is ideal for:

  • Artificial Intelligence (AI) Data Centers
  • High-Performance Computing (HPC) Facilities
  • Cloud Computing Infrastructure
  • Enterprise Data Centers
  • Research and Scientific Computing Centers
  • Financial Trading Platforms
  • Edge Data Centers
  • GPU Computing Clusters
  • Machine Learning Environments
  • Hyperscale Data Centers

Why Choose Delta Two Phase Immersion Cooling?

Delta combines advanced engineering, innovative immersion cooling technology, and energy-efficient design to deliver one of the most effective cooling solutions available for modern data centers. With a PUE below 1.08, cooling capacity of up to 100kW per tank, 84% reduction in cooling power consumption, and robust seismic protection, Delta Two Phase Immersion Cooling helps organizations maximize performance, reduce operating costs, and build sustainable, future-ready data center infrastructure.

Get Quote

Download Brochure

    Download Brochure

      Download Brochure

        Download Brochure

          Download Brochure

            Download Brochure

              Download Brochure

                Download Brochure

                  Download Brochure

                    Download Brochure

                      Download Brochure

                        Download Brochure

                          Download Brochure

                            Download Brochure

                              Download Brochure

                                Download Brochure

                                  Download Brochure

                                    Download Brochure

                                      Download Brochure

                                        Download Brochure

                                          Download Brochure

                                            Download Brochure