Delta Ultron HPH 160 kVA UPS and 200 kVA UPS for medium data centers

HPH SERIES, THREE PHASE UPS, 160 kVA UPS and 200 kVA UPS

The Delta Ultron HPH 200 kVA UPS is a highly reliable
three-phase online double-conversion UPS designed for medium data centers,
enterprise IT infrastructure, industrial facilities and other
mission-critical power applications.

The Delta HPH-200K provides a rated capacity of
200 kVA / 200 kW, making it suitable for organisations
that require dependable power protection for large and sensitive electrical
loads. It helps protect connected systems against power failures, voltage
fluctuations, frequency variations, electrical disturbances and unstable
utility conditions.

With online efficiency up to 96.5%, ECO mode efficiency up to 99%,
input power factor above 0.99 and low input harmonic distortion below 3%,
this 200 kVA online UPS delivers a strong combination of
performance, efficiency, availability and long-term operating savings.

Delta HPH-200K 200 kVA UPS Overview

The Delta Ultron HPH-200K is designed for businesses where continuous
operation is essential. Its true online double-conversion technology
continuously conditions incoming power before supplying electricity to
connected equipment.

This provides a stable and clean power supply for servers, networking
equipment, industrial controls, medical systems, telecom infrastructure,
banking systems and other sensitive applications.

The UPS also supports flexible battery configuration, intelligent battery
monitoring, parallel redundancy, environmental monitoring and advanced
communication options. These features make it suitable for both new
installations and future infrastructure expansion.

Delta 200 kVA UPS Key Specifications

UPS Model Delta Ultron HPH-200K
Rated Capacity 200 kVA / 200 kW
UPS Technology True online double conversion
Phase Configuration Three-phase input and three-phase output
Nominal Input Voltage 220/380 Vac, 230/400 Vac or 240/415 Vac
Input Frequency 40–70 Hz
Input Power Factor Greater than 0.99
Input Harmonic Distortion Below 3%
Output Frequency 50/60 Hz
Online Efficiency Up to 96.5%
ECO Mode Efficiency Up to 99%
Battery Configuration 30–46 batteries; 40 batteries by default
Parallel Expansion Maximum eight UPS units
Maximum Combined Capacity Up to 1.6 MVA
Display 10-inch colour LCD touchscreen
Operating Temperature 0°C to 40°C
Dimensions 600 × 1100 × 1600 mm
Approximate Weight 376 kg


Specifications may vary according to product configuration and project
requirements. Contact MPower India for final technical confirmation.

Key Features of the Delta Ultron HPH 200 kVA UPS

True Online Double-Conversion Technology

The Delta HPH-200K uses true online double-conversion technology to
continuously isolate critical equipment from incoming power disturbances.
It provides stable output during voltage fluctuations, frequency variations,
power interruptions and generator changeovers.

Full 200 kVA and 200 kW Power Rating

The HPH-200K provides a rated capacity of
200 kVA / 200 kW. Its high real-power output makes it
suitable for modern enterprise equipment and mission-critical systems with
demanding electrical loads.

Online Efficiency up to 96.5%

High AC-AC efficiency helps reduce energy loss when the UPS operates
continuously. It can also reduce heat generation, cooling requirements and
long-term operating costs.

ECO Mode Efficiency up to 99%

ECO mode offers efficiency up to 99% when site power conditions permit.
This provides additional energy savings while supporting a lower total cost
of ownership.

Low Input Harmonic Distortion

Input harmonic distortion below 3% helps reduce harmonic pollution affecting
upstream electrical equipment. This improves compatibility with generators,
transformers, cables and distribution systems.

Input Power Factor Above 0.99

The high input power factor supports efficient use of incoming electrical
power and can help reduce unnecessary upstream electrical infrastructure
investment.

Parallel Expansion up to Eight UPS Units

Multiple Delta HPH units can be connected in parallel for additional capacity
or redundancy. Up to eight 200 kVA UPS systems can provide a combined
capacity of up to 1.6 MVA.

Optional Redundant Controller

An optional redundant controller with dual CAN bus and ring connection helps
improve system availability for facilities where continuous operation is a
priority.

Proactive Battery Ageing Detection

Proactive battery ageing detection helps maintenance teams identify potential
battery deterioration and schedule replacement before battery performance
affects system availability.

Flexible Battery Configuration

The UPS supports battery configurations from 30 to 46 pieces. This allows
battery capacity and backup duration to be planned according to the connected
load, available space and project requirements.

10-Inch Colour Touchscreen

The user-friendly colour touchscreen provides convenient access to system
status, alarms, battery information, operating parameters and event logs.

Environmental Monitoring Integration

Information related to security, water leakage, fire and temperature can be
integrated into the UPS and viewed through the LCD interface.

Battery Management System Integration

When used with Delta’s battery management system, detailed battery
information can be integrated into the UPS for improved monitoring and
maintenance planning.

Flexible Cable Entry

Support for top or bottom cable entry makes installation easier across
different electrical-room and data-center layouts. The fixed symmetric
terminal design also helps avoid excessive cable bending.

200 kVA UPS Applications

The Delta Ultron HPH 200 kVA online UPS is suitable for commercial,
industrial and institutional applications that require reliable and
continuous power protection.

Common Applications

  • Medium and enterprise data centers
  • Server rooms and centralised IT systems
  • Enterprise networking infrastructure
  • Industrial automation and process-control systems
  • Manufacturing and production facilities
  • Telecom exchanges and network operation centres
  • Hospitals and healthcare facilities
  • Banking and financial infrastructure
  • Commercial buildings and corporate offices
  • Government and public infrastructure
  • Security and surveillance systems
  • Metro and transportation infrastructure

Benefits of the Delta HPH-200K UPS

  • 200 kVA and 200 kW rated power output
  • True online double-conversion power protection
  • Online efficiency up to 96.5%
  • ECO mode efficiency up to 99%
  • Input harmonic distortion below 3%
  • Input power factor above 0.99
  • Parallel expansion and redundancy up to eight units
  • Combined system capacity up to 1.6 MVA
  • Proactive battery ageing detection
  • Flexible battery configuration from 30 to 46 pieces
  • 10-inch colour LCD touchscreen
  • Environmental and battery monitoring integration
  • Top or bottom cable-entry support
  • Reduced energy loss and operating costs

Delta 160 kVA UPS and 200 kVA UPS Comparison

The Delta Ultron HPH series is available in 160 kVA and 200 kVA capacities.
The appropriate model should be selected after assessing the connected load,
required backup time, future expansion and redundancy requirements.

Specification HPH-160K HPH-200K
Rated Capacity 160 kVA 200 kVA
Rated Real Power 150 kW 200 kW
Online Efficiency Up to 96.5% Up to 96.5%
Approximate Weight 339 kg 376 kg
Suitable For Medium enterprise loads requiring up to 150 kW Higher enterprise loads requiring up to 200 kW

200 kVA UPS Price in India

The Delta 200 kVA UPS price in India depends on the
complete system configuration rather than only the UPS capacity. Battery
backup time, installation requirements, electrical accessories and service
coverage can affect the final project cost.

Factors That Affect the 200 kVA UPS Price

  • Actual connected load in kW
  • Required battery backup duration
  • Battery technology and battery capacity
  • Number of battery strings
  • Standard, parallel or N+1 configuration
  • Input, output and maintenance-bypass panels
  • Battery cabinets or battery racks
  • Power and battery cable requirements
  • SNMP, Modbus or BMS integration
  • Transportation and site-access conditions
  • Installation, testing and commissioning
  • Warranty and UPS AMC coverage

Contact MPower India with your connected load, backup duration, location
and redundancy requirements to receive an accurate Delta HPH-200K
quotation.

200 kVA UPS Installation and Maintenance Support

A 200 kVA UPS installation requires proper load assessment, battery sizing,
cable selection, electrical protection, ventilation planning and professional
commissioning.

MPower India provides support for UPS selection, equipment supply,
battery-bank sizing, installation, testing, commissioning, preventive
maintenance, battery replacement and annual maintenance contracts.

Frequently Asked Questions

What is a 200 kVA UPS?

A 200 kVA UPS is a high-capacity uninterruptible power supply used to
protect large commercial, industrial and IT loads. The Delta HPH-200K
provides a rated output of 200 kVA and 200 kW.

Is the Delta HPH-200K a three-phase UPS?

Yes. The Delta HPH-200K has three-phase input and three-phase output,
making it suitable for large enterprise and industrial electrical loads.

Is a 200 kVA UPS equal to 200 kW?

The relationship between kVA and kW depends on the UPS output power
factor. The Delta HPH-200K is specifically rated at
200 kVA / 200 kW.

How much backup time does a 200 kVA UPS provide?

Backup time depends on the connected load, battery capacity, number of
battery strings, battery condition and system efficiency. The battery bank
must be sized according to the required runtime.

Can Delta HPH UPS units operate in parallel?

Yes. Up to eight Delta HPH UPS units can be connected for capacity
expansion or redundancy, subject to the final system design.

Where is a 200 kVA online UPS commonly used?

It is commonly used in data centers, hospitals, telecom facilities,
manufacturing plants, banking systems, commercial buildings and
enterprise IT infrastructure.

Does the Delta HPH-200K support remote monitoring?

Yes. The UPS supports communication and monitoring options including
Ethernet, RS232, USB, RS485, dry contacts and integration with external
monitoring systems.

Explore Related Delta UPS Products and Services

Get Quote

Download Brochure

    Download Brochure

      Download Brochure

        Download Brochure

          Download Brochure

            Download Brochure

              Download Brochure

                Download Brochure

                  Download Brochure

                    Download Brochure

                      Download Brochure

                        Download Brochure

                          Download Brochure

                            Download Brochure

                              Download Brochure

                                Download Brochure

                                  Download Brochure

                                    Download Brochure

                                      Download Brochure

                                        Download Brochure

                                          Download Brochure

                                            Download Brochure