6 kVA & 10 kVA Online UPS for Critical Power Protection
The Delta Amplon N Series 6 kVA and 10 kVA Online UPS provides reliable single-phase power protection for servers, networking equipment, POS systems, ATMs, office infrastructure and mission-critical commercial applications.
Built on true online double-conversion technology, the N Series delivers zero transfer time, unity output power factor and efficient power conditioning to protect sensitive equipment from outages, voltage fluctuations and electrical disturbances.
- 6 kVA / 6 kW & 10 kVA / 10 kW
- True online double conversion
- Unity output power factor
- Up to 95% AC-AC efficiency
- Up to 98% ECO mode efficiency
- Parallel redundancy up to 4 units
Delta Amplon N Series 6/10 kVA Online UPS
LCD Panel and Communication Interfaces
Designed for Critical Business Applications
Choose Between 6 kVA and 10 kVA Online UPS
The correct UPS capacity depends on connected load, required backup duration, equipment type, starting load and future power requirements.
6 kVA Online UPS
A compact single-phase online UPS for server racks, workstations, networking equipment, POS systems, office infrastructure and critical electronic loads.
10 kVA Online UPS
Designed for higher critical loads including small server rooms, IT infrastructure, ATMs, commercial equipment and production systems requiring dependable continuous power.
Need help selecting 6 kVA or 10 kVA?
Share your connected load and required backup time. MPower can recommend the suitable UPS and battery configuration for your application.
High-Performance 10 kVA Online UPS Technology
The Amplon N Series combines compact construction, high efficiency and advanced power protection for business-critical applications.
True Online Double Conversion
The UPS continuously conditions incoming power and supplies stable pure sine wave output to connected equipment.
Zero Transfer Time
During a mains power failure, connected critical equipment continues operating without transfer interruption.
Unity Output Power Factor
The 6 kVA model delivers up to 6 kW and the 10 kVA model delivers up to 10 kW, maximizing available UPS capacity.
High Energy Efficiency
AC-to-AC efficiency reaches up to 95%, while ECO mode efficiency reaches up to 98% to help reduce operating losses.
N+X Parallel Redundancy
Up to four compatible UPS units can operate in parallel for capacity expansion and improved power-system redundancy.
Advanced DSP Control
Digital Signal Processor control provides rapid processing, simplified control architecture and enhanced system stability.
Generator Compatible
Generator compatibility helps maintain reliable power protection during prolonged mains outages and generator operation.
Intelligent Battery Management
Intelligent charging and battery management help optimize battery performance, reliability and service life.
Variable Fan Speed Control
Multi-stage automatic fan regulation helps reduce audible noise, improve efficiency and extend fan service life.
Flexible UPS Monitoring
LCD, LED indicators, RS-232, USB, REPO, parallel ports and a Smart Slot provide convenient local and remote management options.
Designed to Reduce UPS Space and Operating Cost
The Amplon N Series is engineered to provide high usable power from a compact footprint, making it suitable for installations where equipment-room space and energy efficiency are important.
Compact Footprint
Dimensions of approximately 190 × 390 × 325 mm help conserve valuable space for servers, networking equipment and other critical infrastructure.
Lower Power Losses
High operating efficiency can reduce wasted energy, cooling requirements and long-term electricity costs.
Reduced Battery Usage
A wide input operating range allows the UPS to tolerate varying utility conditions without unnecessarily switching to battery power.
Scalable Protection
Parallel capability allows businesses to expand protected capacity or implement redundancy as operational requirements grow.
Where 6 kVA and 10 kVA Online UPS Systems Are Used
The N Series is suitable for commercial, IT, banking, telecom and production environments requiring clean and uninterrupted power.
Delta N Series 6 kVA & 10 kVA Online UPS Specifications
Core technical specifications for the Delta Amplon N-6K and N-10K single-phase online UPS models.
From UPS Selection to Installation & AMC
Correct UPS selection requires more than choosing a kVA rating. MPower can assist with load assessment, battery sizing, installation and ongoing support.
Load Assessment
Evaluation of connected equipment, actual load, power factor, criticality and future expansion.
UPS Selection
Recommendation of the appropriate N-6K or N-10K UPS according to your application requirements.
Battery Sizing
Battery-bank sizing based on required backup duration, connected load and operating conditions.
Installation & Service
Support for supply, installation, commissioning, preventive maintenance, battery replacement and UPS AMC requirements.
Questions About 6 kVA & 10 kVA Online UPS Systems
What is a 10 kVA Online UPS used for?
A 10 kVA Online UPS is commonly used to protect small server rooms, networking infrastructure, workstations, ATMs, POS systems, office equipment, production equipment and other sensitive business loads requiring uninterrupted conditioned power.
What is the difference between the 6 kVA and 10 kVA models?
The N-6K provides a rated capacity of 6 kVA / 6 kW, while the N-10K provides 10 kVA / 10 kW. The suitable model depends primarily on your connected load, future expansion and required operating margin.
Is the Delta N Series a true online UPS?
Yes. The Amplon N Series uses true online double-conversion topology to continuously condition power and provide zero-transfer-time protection to connected equipment.
Does the 10 kVA UPS provide 10 kW output?
Yes. The N-10K has a unity output power factor and is rated at 10 kVA / 10 kW, allowing the full rated capacity to be used for compatible connected loads.
Can multiple N Series UPS units run in parallel?
Yes. Compatible N Series units support parallel operation of up to four UPS systems for capacity expansion and N+X redundancy.
Is the N Series UPS compatible with generators?
Yes. Generator compatibility helps the UPS provide dependable power protection during prolonged utility outages when the facility is operating on generator power.
How much battery backup will a 10 kVA UPS provide?
Backup duration depends on the actual connected load, battery capacity, battery configuration, battery condition and required runtime. MPower can size the battery bank according to your required backup duration.
What is the price of a 10 kVA Online UPS?
The final 10 kVA Online UPS price depends on the UPS configuration, battery-bank capacity, required backup time, accessories, installation requirements and project location. Request a quotation for an accurately sized solution.
Get a Quote for Delta 6 kVA or 10 kVA Online UPS
Share your connected load, application and required backup time. MPower will help recommend the suitable Delta Amplon N Series UPS and battery configuration for your requirement.