The RowCool CW Chilled Water Cooling System is an advanced precision cooling solution designed for modern data centers, high-density IT environments, server rooms, telecom data centers, colocation facilities, and mission-critical infrastructure. Engineered to provide reliable temperature control, exceptional cooling efficiency, and maximum system availability, this cooling system helps maintain optimal operating conditions for critical IT equipment.
Designed for high-density rack deployments, the Chilled Water Cooling System delivers efficient heat removal directly at the source. By cooling close to the rack, it improves airflow management, reduces hot spots, and supports stable performance for high-power-density servers and network equipment.
Advanced Chilled Water Cooling System for Data Center Cooling
As rack power density continues to increase, traditional room-based cooling systems may struggle to deliver the required cooling performance. The RowCool CW Chilled Water Cooling System is designed to solve this challenge by providing targeted cooling close to the heat source.
With optimized chilled water heat exchanger design, variable speed fan technology, intelligent flow control, and scalable architecture, this precision cooling system helps data centers reduce energy consumption while maintaining reliable and efficient IT operations.
Why Choose Chilled Water Cooling System?
High-Efficiency Chilled Water Cooling
The Chilled Water Cooling System uses an optimized heat exchanger design to deliver superior cooling performance for high-density data center environments. It helps maintain stable operating temperatures while improving overall cooling efficiency.
Ideal for High-Density Rack Applications
Designed for high-power-density server racks, the system removes heat directly within the row. This helps reduce hot spots, improve airflow control, and support reliable operation of mission-critical IT equipment.
Energy-Saving Operation
The system supports high-temperature chilled water applications, helping facilities reduce energy consumption. When chilled water temperature increases from 5°C to 12°C, outdoor cooling units can reduce power consumption by up to 15–20%.
Intelligent Cooling Performance
Variable speed fans and variable chilled water flow control help adjust cooling output based on demand, improving operational efficiency and reducing unnecessary energy usage.
Precision Cooling for Mission-Critical IT Environments
The RowCool CW Chilled Water Cooling System is built to provide accurate and dependable cooling for environments where temperature control is essential.
Targeted Heat Removal
The system removes heat close to the source, improving cooling efficiency for high-density racks and reducing the burden on room-based cooling systems.
Stable Temperature Control
Precision cooling technology helps maintain consistent environmental conditions for servers, storage systems, networking devices, and critical IT infrastructure.
Reduced Hot Spots
By delivering cooling directly within the row, the system minimizes localized hot spots and improves overall airflow distribution.
Reliable Rack-Level Cooling
The rack-based cooling approach supports dependable performance for high-density IT deployments and mission-critical applications.
Energy-Efficient Cooling Operation
The Chilled Water Cooling System is designed to reduce operating costs while maintaining high cooling performance.
High-Temperature Chilled Water Support
The optimized heat exchanger allows efficient operation in high-temperature chilled water environments, helping reduce cooling energy demand.
Variable Speed Fan Technology
Continuously variable speed fans automatically adjust airflow according to cooling requirements, helping lower energy consumption.
Variable Flow Control System
The intelligent variable chilled water flow control system optimizes cooling performance and improves overall efficiency.
Lower Operating Costs
Energy-saving design and demand-based cooling help reduce electricity usage and support long-term operational savings.
High Availability Features
The RowCool CW Chilled Water Cooling System includes advanced reliability features to support continuous operation in critical cooling environments.
Dual Power Supply Design
Built-in dual power supplies with dual input sources provide enhanced reliability and help maintain continuous cooling for critical applications.
Hot-Swappable Components
Rectifiers and cooling fans support hot-swappable replacement, reducing maintenance time and minimizing unnecessary downtime.
Built-In Water Leak Detection
The integrated leak detection system continuously monitors for water leakage and provides immediate alerts to help prevent equipment damage and operational disruption.
Group Control and Backup Support
Group control functionality and backup operation improve cooling redundancy and overall system reliability.
Manual Dehumidification Function
The built-in manual dehumidification feature enables fast and precise humidity control to maintain optimal data center environmental conditions.
Flexible Installation and Scalability
The Chilled Water Cooling System is designed for flexible deployment, easy installation, and scalable growth.
Top and Bottom Pipe Entry Options
The chilled water piping system supports both top and bottom pipe connections, allowing flexible installation according to site requirements.
Modular Rack-Based Design
The modular design allows easy expansion as cooling requirements increase, helping organizations scale data center infrastructure efficiently.
Mobility Support
Integrated wheels allow easy movement and positioning during installation, maintenance, or data center reconfiguration.
Remote Monitoring Capability
Optional SNMP-based remote monitoring allows facility managers to monitor cooling performance, alarms, and operating status from centralized management systems.
Advanced Air Filtration
The RowCool CW Chilled Water Cooling System includes filtration options to support clean airflow and equipment protection.
High-Efficiency Disposable Filters
High-efficiency disposable filters rated at MERV 8 according to ASHRAE 52.2 help maintain clean airflow and protect critical IT equipment.
Optional Washable Filters
Optional washable MERV 1 filters provide an economical filtration option to help reduce maintenance and replacement costs.
Cleaner Cooling Airflow
Effective air filtration helps reduce dust and contaminants, supporting better cooling performance and equipment reliability.
Intelligent Monitoring and Management
The Chilled Water Cooling System includes intelligent monitoring features that help improve operational visibility, maintenance planning, and system reliability.
Chilled Water Flow Monitoring
A built-in vortex wafer flow meter continuously monitors chilled water flow and provides real-time system status information.
Real-Time Performance Visibility
Integrated monitoring helps operators identify performance trends, optimize cooling efficiency, and maintain reliable operation.
Comprehensive System Protection
Remote monitoring capabilities provide proactive alerts and system insights, helping reduce downtime and improve maintenance planning.
Centralized Management Support
Optional SNMP monitoring allows cooling data and alarm information to be integrated into centralized infrastructure management systems.
Key Features of Chilled Water Cooling System
High-Performance Chilled Water Cooling
Designed to provide efficient precision cooling for modern data centers and high-density IT environments.
High-Density Rack Cooling
Removes heat close to the rack to reduce hot spots and improve airflow management.
Variable Speed Fan Technology
Automatically adjusts fan speed based on cooling demand to reduce energy consumption.
Variable Chilled Water Flow Control
Optimizes chilled water usage and improves cooling efficiency.
Dual Power Supply
Enhances system reliability for mission-critical cooling applications.
Hot-Swappable Fans and Rectifiers
Supports easier maintenance and reduces downtime during component replacement.
Built-In Leak Detection
Provides immediate alerts in case of water leakage to protect critical equipment.
Group Control and Backup Operation
Improves cooling redundancy and system availability.
Top and Bottom Pipe Entry
Supports flexible installation for different site layouts.
Remote Monitoring Support
Optional SNMP-based monitoring enables centralized performance tracking and alarm management.
Advanced Air Filtration
Includes MERV 8 disposable filters with optional washable MERV 1 filters.
Intelligent Flow Monitoring
Built-in vortex wafer flow meter provides real-time chilled water flow visibility.
Suitable Applications
High-Density Data Centers
Provides targeted cooling for high-power-density server racks and IT equipment.
Enterprise Data Centers
Supports reliable and efficient cooling for enterprise IT infrastructure and business-critical systems.
Server Rooms
Maintains stable operating temperatures for servers, storage systems, and networking equipment.
Edge Computing Facilities
Delivers compact and efficient cooling for distributed IT environments and edge infrastructure.
Colocation Facilities
Supports scalable and efficient cooling for multi-tenant data center deployments.
IT Infrastructure Environments
Provides precision cooling for networking systems, communication equipment, and critical IT loads.
Mission-Critical Facilities
Ensures dependable cooling performance for environments where downtime can affect operations.
Network Operation Centers
Supports continuous cooling for monitoring equipment, communication systems, and IT infrastructure.
Telecom Data Centers
Provides reliable temperature control for telecom networks and communication infrastructure.
Precision Environmental Control Applications
Maintains controlled temperature and humidity conditions for sensitive equipment environments.
Product Benefits
Reliable Temperature Control
The Chilled Water Cooling System helps maintain optimal operating temperatures for mission-critical IT equipment.
Improved Cooling Efficiency
Targeted rack-level cooling and optimized heat exchanger design improve cooling performance in high-density environments.
Reduced Energy Consumption
High-temperature chilled water support, variable speed fans, and variable flow control help lower energy usage.
Enhanced System Availability
Dual power supply, hot-swappable components, group control, and backup support improve cooling reliability.
Lower Downtime Risk
Leak detection, remote monitoring, and proactive alerts help reduce the risk of equipment damage and operational disruption.
Flexible Deployment
Top and bottom pipe entry, modular architecture, and mobility support make installation and expansion easier.
Cleaner Airflow
MERV 8 disposable filters and optional washable filters help protect equipment from dust and contaminants.
Long-Term Operational Efficiency
Energy-saving design, scalable cooling architecture, and intelligent management help reduce operating costs over time.
Technical Highlights
Cooling System Type
Chilled water precision cooling system.
Cooling Application
High-density rack cooling and data center cooling.
Cooling Capacity
29 kW and 43 kW models.
Cooling Technology
Optimized chilled water heat exchanger design.
Fan Technology
Continuously variable speed fan operation.
Water Flow Control
Variable chilled water flow control system.
Power Reliability
Dual power supply with dual input sources.
Maintenance Features
Hot-swappable rectifiers and cooling fans.
Leak Protection
Built-in water leak detection system.
Humidity Control
Manual dehumidification function.
Pipe Entry
Top and bottom chilled water pipe entry options.
Mobility
Integrated wheels for easy positioning and deployment.
Monitoring
Built-in chilled water flow monitoring with vortex wafer flow meter.
Remote Management
Optional SNMP-based remote monitoring.
Filtration
MERV 8 disposable filters and optional washable MERV 1 filters.
Applications
High-density data centers, enterprise data centers, server rooms, edge computing facilities, colocation facilities, telecom data centers, network operation centers, IT infrastructure environments, and precision environmental control applications.
Chilled Water Cooling System for Modern Data Centers
The RowCool CW Chilled Water Cooling System is a powerful and energy-efficient precision cooling solution designed to meet the demands of modern data centers and high-density IT environments. Combining intelligent cooling technology, high availability features, flexible deployment options, advanced filtration, and remote monitoring capabilities, it helps organizations maintain optimal operating conditions for mission-critical IT equipment.
For businesses looking for a reliable Chilled Water Cooling System for data centers, server rooms, telecom facilities, edge computing environments, and high-density rack deployments, the RowCool CW delivers exceptional cooling performance, scalability, energy efficiency, and long-term operational value.